WSI MX/PX-Titan Expertise

Titanium Spinal Fusion System

One Implant - Many Options

In cooperation with its clinical development partners, PETER BREHM GmbH first introduced a titanium Spinal Fusion System in 1993. Over the years the system has undergone continuous further development. The WSI MX/PX-Titan Expertise system can be used for both simple single-segment open operations and also for anterior or posterior multisegmental fusion in either open or minimally invasive procedures. The screws of the WSI MX/PX-Titan Expertise Integration version have a BONIT® coating for improved osseointegration. This version also has a distal fenestration and can be augmented with bone cement.

Sterility

All implants are supplied in sterile packaging

  • Simple documentation
  • Complete traceability
  • Infection from contaminated implants excluded

Identical implants

For open and minimally invasive procedures

  • Simplified inventory
  • Polyaxial and monoaxial screws available for MISS
  • Instrumentation technique can be changed intraoperatively

Safety and Stability

DLC-coated Grub Screws with Undercut Saw Tooth Threading

  • Grubs screws are easy to place and securely tighten
  • Screw-rod connection is highly stable

Highest precision

All pedicle screws – polyaxial and monoaxial – are cannulated

  • Can be placed over K wire even with open instrumentation technique, thus ensuring maximum precision

Stable fixation

Single thread with tapered core

  • Reliable permanent fixation in the pedicle

Soft tissue sparing

Low profile implants

  • Stable, low transverse connectors
  • Rod diameter of only 5.0 mm with high stability

Reliable fixation in poor quality bone with

BONIT® -coated augmentable screw versions with the same geometry

  • Reliable fixation in the pedicle
  • Better and quicker osseointegration
  • Augmentation option in osteoporosis
  • Identical instruments for coated and uncoated pedicle screws
WSI MX/PX-Titan Expertise Integration

Simple and reliable augmentation technique

Distal cap option for augmentation

  • Optional augmentation
  • Minimized risk of cement leakage
  • Steep learning curve

Summary of Safety and Clinical Performance

The Summary of Safety and Clinical Performance for the specific product system WSI MX/PX-Titan Expertise und WSI MX/PX-Titan Expertise Integration will be provided upon request by Peter Brehm GmbH via info@peter-brehm.de or +49 (0) 9135 7103-0.

Downloads

All product information and surgical techniques are visible only for medical professionals after login. If you are not yet a registered user, you can request your login data here.

Please visit www.peter-brehm.de/ifu to download electronic instruction for use.

Ask us if you are unable to find the desired information.

Forgot your password?

Please get in touch with us with our contact form and we will send you a new password.
Reset Password

Return to login form